Skip to content

Optimize MS2 value peak extraction - #775

Open
YukiMatsuzawa wants to merge 1 commit into
masterfrom
copilot/yukimatsuzawa-performance-hotspot-fix
Open

Optimize MS2 value peak extraction#775
YukiMatsuzawa wants to merge 1 commit into
masterfrom
copilot/yukimatsuzawa-performance-hotspot-fix

Conversation

@YukiMatsuzawa

Copy link
Copy Markdown
Contributor

Summary

  • eliminate the preliminary full scan used only to count matching MS2 spectra
  • collect value peaks during the existing extraction pass
  • preserve the returned per-m/z arrays and ordering

Performance audit: 10 opportunities

  1. Implemented — DataAccess.GetMs2ValuePeaks: remove the duplicate provider traversal used to pre-count results; high impact for large raw-data ranges and low implementation risk.
  2. DataAccess.GetMs2Peaklist: cache/reuse spectrum eligibility checks when multiple product ions are extracted from the same precursor window instead of reloading and filtering the same scans for every product m/z.
  3. DataAccess.GetMs2ValuePeaks: compute intensities for sorted target m/z values with a shared monotonic peak cursor and avoid repeated setup when target lists are reused across files.
  4. DataAccess.GetDriftChromatogramByRtMz: replace repeated ContainsKey plus indexer lookups in nested dictionaries with TryGetValue to reduce hash lookups in the inner peak loop.
  5. DataAccess.GetDriftChromatogramByRtMz: replace per-peak double[] allocations with a value-oriented accumulator to reduce GC pressure during ion-mobility extraction.
  6. SpectrumViewModel and SplitSpectrumsViewModel: maintain a membership set for drag/drop duplicate checks instead of linear Contains scans as displayed scan counts grow.
  7. SpectrumViewModel and SplitSpectrumsViewModel: combine the repeated spectrum min/max enumerations per collection-change event so each spectrum is traversed once per axis update.
  8. DataAccess.IsSWATH: perform one pass over MS2 spectra rather than materializing multiple LINQ sequences and enumerating them repeatedly.
  9. DataAccess.GetBaselineCorrectedPeaklistByMassAccuracy: reserve output capacity from the input peak count to avoid repeated list growth during chromatogram construction.
  10. DataAccess.GetDriftChromatogramByScanRtMz: use the existing RT index lookup to bound both directional scans before loading spectra, reducing provider calls outside the requested RT window.

Validation

  • dotnet test tests\\MSDIAL5\\MsdialCoreTests\\MsdialCoreTests.csproj --no-restore --filter FullyQualifiedName~DataAccessTests

Co-authored-by: Copilot App <223556219+Copilot@users.noreply.github.com>
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant