A collection of Arduino sketches to read Kamstrup FlowIQ 2200 data via CC1101.
Ranging from basic frame reception to ISR-stable MQTT integration.
-
Big Sketch (Full + Compact Frames):
- flowIQ2200_Full.ino
- Receives both 0x79 (Compact Frame) and 0x78 (Full Frame).
- A telegram is transmitted every 16 seconds. First, 7 compact are sent, followed by 1 full.
- This adds complexity due to handling Full Frames and mechanisms like GDO2 threshold burst detection.
-
Small Sketch (only Compact Frames):
- flowIQ2200_Compact.ino
- Receives only 0x79 (Compact Frame).
- This is the basic approach, as it is significantly simpler in structure, but still uses polling.
- Simple, but can be blocked by other tasks (like WiFi).
- The Compact Frame contains all relevant data and is transmitted every 16 seconds.
-
ISR Version (only Compact Frames):
⚠️ Recommended⚠️ - flowIQ2200_Compact_ISR.ino
- Receives only 0x79 (Compact Frame)
- Uses ISR to ensure maximum stability while multitasking with services such as WiFi/MQTT.
- The Compact Frame contains all relevant data and is transmitted every 16 seconds.
-
MQTT Version (The "All-rounder"):
⚠️ Also Recommended⚠️ - flowIQ2200_MQTT.ino
- The all-in-one solution for seamless integration.
- Receives only 0x79 (Compact Frame)
- Features high stability via ISR-based reception.
- The Compact Frame contains all relevant data and is transmitted every 16 seconds.
- WiFi: Includes BSSID scanning and robust auto-reconnect logic.
- MQTT: Automated publishing via PubSubClient with built-in auto-reconnect.
-
Data included in telegrams:
- Total Consumption (Total Volume): Current overall consumption in m³
- Month-Start Consumption (Target Volume): Consumption at the beginning of the current month in m³
- Current Flow: Instantaneous flow rate in L/h
- Maximum Flow: Maximum flow within the interval in L/h
- Temperatures (Min/Max): Minimum and maximum temperatures in °C
- Status: Status information of the meter
- Date (Target Date): Date of the month start (e.g., 2026-04-01)
-
Promiscuous Mode:
Allows passive listening to all M-Bus messages in range to identify the meter ID. -
Multi-step check:
- ID Check: Filters for your specific Meter-ID.
- AES Decryption: Uses your individual 16-byte key to unlock the payload.
- CRC Verification (EN 13757): The code calculates a 16-bit checksum over the decrypted data and compares it with the transmitted CRC bytes.
-
RSSI monitoring
The Compact Frame (CI=0x79) implementation was the main goal and took most of the effort.
The Full Frame (CI=0x78) was added afterwards purely for comparison and validation — and frankly, it was a pain to get working reliably with the CC1101. FIFO limits, burst handling (GDO2), timing… all that complexity for basically no real benefit.
Some sources (e.g., https://github.com/erikxson/watermeter-flowiq2200) claim that Compact and Full Frames contain different data sets — especially for flow values (1-byte vs. 2-byte). That claim was the reason to dig deeper.
After analyzing both frame types from this specific meter, the result is simple:
all relevant data (Total Volume, Target Volume, Flow, Temperature, Status, etc.) is already present in the Compact Frame.
The Full Frame doesn’t add anything useful here. It just confirms that the Compact Frame is complete.
Conclusion:
Handling Full Frames is unnecessary overhead for this device.
Compact Frames (CI=0x79) are simpler, more robust, and get the job done.
-
Required Hardware
- ESP32 DevBoard:
- CC1101 RF Module: Ensure you use the 868 MHz version (wM-Bus operates at 868.95 MHz).
-
Libraries
-
Crypto (by Rhys Weatherley):
- Provides
AES.handCBC.hfor decryption.
- Provides
-
CC1101_ESP_Arduino (by wischbgr):
- The specialized driver for using CC1101 with ESP32 SPI.
-
-
Wiring Diagram
The CC1101 communicates with the ESP32 via the SPI bus. Since both devices operate at 3.3V, no level shifters are needed.
| CC1101 Pin | ESP32 Pin (Standard) | Description |
|---|---|---|
| VCC | 3V3 | Power Supply (3.3V) |
| GND | GND | Ground |
| SI (MOSI) | GPIO 23 | Master Out Slave In |
| SO (MISO) | GPIO 19 | Master In Slave Out |
| SCK | GPIO 18 | Serial Clock |
| CSN (SS) | GPIO 5 | Chip Select |
| GDO0 | GPIO 27 | RX Interrupt (Data Ready) |
| GDO2 | GPIO 26 | FIFO Threshold (For long packets) |
-
Configuration in Sketch
- Before uploading, update these variables in your
.inofile:meterId: The ID found on your meter's housing (entered in Hex).key: The 32-character Hex key provided by your water utility company.
- Before uploading, update these variables in your
-
Serial Log
====== Packet #398 RSSI=-86 dBm ======
[RAW] Len=52 Link-CI=0x8D
[RAW] 44 37 2C 38 19 65 53 3C 16 8D 20 75 33 9A BC ... (Encrypted data)
[ID] Meter-ID OK
[DEC] Application-CI=0x79 plainLen=34
[DEC] D6 F0 79 05 09 B1 79 00 00 00 00 E6 E4 00 ... (Decrypted plain text)
[CRC] read=0xF0D6 calc=0xF0D6 OK
[CI] Compact Frame (0x79) - FlowIQ 2200
[VAL] total_m3 = 62.755 m3
[VAL] target_m3 = 58.598 m3
[VAL] target_date = 2026-04-01
[VAL] flow_now = 0 L/h
[VAL] status = 0x00000000 OK
Original Raw Payload: 44 37 2C 38 19 65 53 3C 16 8D 20 2F F0 36 BC 20 E4 82 60 05 CC 49 F6 D4 4E 27 2A B1 1C 2E 29 D6 99 B4 4C 43 C3 78 BC 78 CC ED F6 A1 3A 09 0F 6B 78 FB 27 04
Decrypted Plain Payload: 35 2A 79 05 09 61 78 00 00 00 00 E6 E4 00 00 5C 02 05 50 00 05 50 00 41 34 0B 0D EB 01 DD F3 00 00 0D
Click here to expand the byte-by-byte table
| Byte Index | Value (Hex) | Interpretation |
|---|---|---|
| 0 | 35 |
Part of CRC Header (Byte 0 of 2) |
| 1 | 2A |
Part of CRC Header (Byte 1 of 2) |
| 2 | 79 |
Application CI (0x79) |
| 3 | 05 |
Part of Kamstrup Header (Byte 0 of 4) |
| 4 | 09 |
Part of Kamstrup Header (Byte 1 of 4) |
| 5 | 61 |
Part of Kamstrup Header (Byte 2 of 4) |
| 6 | 78 |
Part of Kamstrup Header (Byte 3 of 4) |
| 7 | 00 |
Part of Status Value (LSB, 00 00 00 00) |
| 8 | 00 |
Part of Status Value (Byte 1, 00 00 00 00) |
| 9 | 00 |
Part of Status Value (Byte 2, 00 00 00 00) |
| 10 | 00 |
Part of Status Value (MSB, 00 00 00 00) -> 0x00000000 OK |
| 11 | E6 |
Part of Target Volume (LSB, E6 E4 00 00) |
| 12 | E4 |
Part of Target Volume (Byte 1, E6 E4 00 00) |
| 13 | 00 |
Part of Target Volume (Byte 2, E6 E4 00 00) |
| 14 | 00 |
Part of Target Volume (MSB, E6 E4 00 00) -> 58.598 m³ |
| 15 | 5C |
Part of Max Flow (LSB, 5C 02) |
| 16 | 02 |
Part of Max Flow (MSB, 5C 02) -> 604 L/h |
| 17 | 05 |
Part of Manufacturer Data (Byte 0 of 6) |
| 18 | 50 |
Part of Manufacturer Data (Byte 1 of 6) |
| 19 | 00 |
Part of Manufacturer Data (Byte 2 of 6) |
| 20 | 05 |
Part of Manufacturer Data (Byte 3 of 6) |
| 21 | 50 |
Part of Manufacturer Data (Byte 4 of 6) |
| 22 | 00 |
Part of Manufacturer Data (Byte 5 of 6) |
| 23 | 41 |
Part of Target Date (Byte 0 of 2) |
| 24 | 34 |
Part of Target Date (Byte 1 of 2) -> 2026-04-01 |
| 25 | 0B |
Min Temperature -> 11 °C |
| 26 | 0D |
Max Temperature -> 13 °C |
| 27 | EB |
Part of Current Flow (LSB, EB 01) |
| 28 | 01 |
Part of Current Flow (MSB, EB 01) -> 491 L/h |
| 29 | DD |
Part of Total Volume (LSB, DD F3 00 00) |
| 30 | F3 |
Part of Total Volume (Byte 1, DD F3 00 00) |
| 31 | 00 |
Part of Total Volume (Byte 2, DD F3 00 00) |
| 32 | 00 |
Part of Total Volume (MSB, DD F3 00 00) -> 62.429 m³ |
| 33 | 0D |
End Value / Extra -> 13 |
Original Raw Payload: 44 37 2C 38 19 65 53 3C 16 8D 20 30 F1 36 BC 20 AD 5B 75 1A 64 AF 2F 6E FC B2 CA B5 62 6E B9 97 B9 81 21 CD 42 F9 10 CB 70 7D AB BE 24 35 41 F6 16 B4 2C 03 6C 5D A9 89 95 E1 B7 56 97 42 DA AC 39 80 91 D1 FE EA A4 9B 1B
Decrypted Plain Payload: 6F C4 78 04 FF 23 00 00 00 00 44 13 E6 E4 00 00 52 3B 5C 02 06 FF 1B 05 50 00 05 50 00 42 6C 41 34 61 67 0B 51 67 0D 02 3B EB 01 04 13 DD F3 00 00 81 01 E7 FF 0F 0D
Click here to expand the byte-by-byte table
| Byte Index | Value (Hex) | Interpretation |
|---|---|---|
| 0 | 6F |
Part of CRC Header (Byte 0 of 2) |
| 1 | C4 |
Part of CRC Header (Byte 1 of 2) |
| 2 | 78 |
Application CI (0x78) |
| 3 | 04 |
DIF_FF for Status Marker |
| 4 | FF |
VIF_FF for Status Marker |
| 5 | 23 |
Manufacturer Code for Status Marker |
| 6 | 00 |
Part of Status Value (LSB, 00 00 00 00) |
| 7 | 00 |
Part of Status Value (Byte 1, 00 00 00 00) |
| 8 | 00 |
Part of Status Value (Byte 2, 00 00 00 00) |
| 9 | 00 |
Part of Status Value (MSB, 00 00 00 00) -> 0x00000000 OK |
| 10 | 44 |
DIF for Total Volume |
| 11 | 13 |
VIF for Total Volume |
| 12 | E6 |
Part of Target Volume (LSB, E6 E4 00 00) |
| 13 | E4 |
Part of Target Volume (Byte 1, E6 E4 00 00) |
| 14 | 00 |
Part of Target Volume (Byte 2, E6 E4 00 00) |
| 15 | 00 |
Part of Target Volume (MSB, E6 E4 00 00) -> 58.598 m³ |
| 16 | 52 |
DIF for Max Flow |
| 17 | 3B |
VIF for Max Flow |
| 18 | 5C |
Part of Max Flow (LSB, 5C 02) |
| 19 | 02 |
Part of Max Flow (MSB, 5C 02) -> 604 L/h |
| 20 | 06 |
DIF_FF for Manufacturer Marker |
| 21 | FF |
VIF_FF for Manufacturer Marker |
| 22 | 1B |
Manufacturer Code for Manufacturer Marker |
| 23 | 05 |
Part of Manufacturer Data (Byte 0 of 6) |
| 24 | 50 |
Part of Manufacturer Data (Byte 1 of 6) |
| 25 | 00 |
Part of Manufacturer Data (Byte 2 of 6) |
| 26 | 05 |
Part of Manufacturer Data (Byte 3 of 6) |
| 27 | 50 |
Part of Manufacturer Data (Byte 4 of 6) |
| 28 | 00 |
Part of Manufacturer Data (Byte 5 of 6) |
| 29 | 42 |
DIF for Target Date |
| 30 | 6C |
VIF for Target Date |
| 31 | 41 |
Part of Target Date (Byte 0 of 2) |
| 32 | 34 |
Part of Target Date (Byte 1 of 2) -> 2026-04-01 |
| 33 | 61 |
DIF for Min Temperature |
| 34 | 67 |
VIF for Min Temperature |
| 35 | 0B |
Min Temperature -> 11 °C |
| 36 | 51 |
DIF for Max Temperature |
| 37 | 67 |
VIF for Max Temperature |
| 38 | 0D |
Max Temperature -> 13 °C |
| 39 | 02 |
DIF for Current Flow |
| 40 | 3B |
VIF for Current Flow |
| 41 | EB |
Part of Current Flow (LSB, EB 01) |
| 42 | 01 |
Part of Current Flow (MSB, EB 01) -> 491 L/h |
| 43 | 04 |
DIF for Total Volume |
| 44 | 13 |
VIF for Total Volume |
| 45 | DD |
Part of Total Volume (LSB, DD F3 00 00) |
| 46 | F3 |
Part of Total Volume (Byte 1, DD F3 00 00) |
| 47 | 00 |
Part of Total Volume (Byte 2, DD F3 00 00) |
| 48 | 00 |
Part of Total Volume (MSB, DD F3 00 00) -> 62.429 m³ |
| 49 | 81 |
DIF_FF for Ext. Metadata |
| 50 | 01 |
VIF_FF for Ext. Metadata |
| 51 | E7 |
Manufacturer Code (Part 1) |
| 52 | FF |
Manufacturer Code (Part 2) |
| 53 | 0F |
VIF_FF (Continuation) for Ext. Metadata |
| 54 | 0D |
End Value / Extra -> 13 |