Unreleased
==========

**BREAKING CHANGES**: tank energy values were wrong in two independent
ways - a 2.5x unit-scale error and two actively misleading field names -
and both are corrected. Reported tank energy is now 2.5x smaller and two
public field names are removed.

Changed
-------
- **Energy unit scale corrected.** ``totalEnergyCapacity`` and ``availableEnergyCapacity`` were
scaled by 10 on the assumption the device reported 10 Wh units. It does
not. Because ``totalEnergyCapacity`` is a whole-tank quantity, its slope
against the setpoint measures the quantum with no stratification
assumption: on a 65-gallon NWP500 that is 70.25 raw counts per Kelvin.
The field turns out to be bimodal - at a fixed setpoint it takes one of
two values exactly 2 degC apart - but both branches give the same slope
to within 0.2%, so the quantum is unaffected. Converting to Watt-hours needs a
water mass, and a "65 gallon" tank does not hold 65 gallons - so taking
the quantum to be round, as every other conversion in this protocol is,
4 Wh/count is the only candidate implying a water volume below the
nameplate (241.7 L). Two further checks agree: 183 individual heating
recoveries give 4.11 Wh/count by a noisier route, and integrating
``currentInstPower`` over them implies a heat-pump COP of 2.89 at the new
scale against 7.02 at the old, the latter being physically impossible.
**Reported tank energy is now 2.5x smaller.**
Historical series logged from earlier versions need rescaling by 0.4 to
be comparable.

- **Energy fields renamed.**
``availableEnergyCapacity`` is not available energy - it is the energy
still *needed* to reach the setpoint. It falls as the tank heats and
reaches zero when the tank is fully charged, so code treating it as
stored energy had the signal backwards (regression against mean tank
temperature: negative slope, R-squared 0.93, zero crossing at the
setpoint). Likewise ``totalEnergyCapacity`` is not a fixed tank size but
the cost of a full recovery to the *current setpoint*, measured from the
device's own minimum setpoint of 104.9 degF; it moves by about 140 Wh
per 0.5 degC of setpoint change.

.. code-block:: python

# OLD (removed)
status.total_energy_capacity # 15800.0
status.available_energy_capacity # 11660.0

# NEW
status.full_recovery_energy # 6320.0
status.energy_to_setpoint # 4664.0

The protocol field names on the wire are unchanged. CLI rows are
relabelled from "Total Capacity"/"Available Capacity" to
"Full Recovery"/"Energy to Setpoint".

Added
-----
- **``DeviceStatus.usable_energy``**: drawable energy in Watt-hours,
computed as ``full_recovery_energy - energy_to_setpoint``. Both raw
fields are measured from the setpoint, so neither is a state of charge;
subtracting them cancels the setpoint and leaves the tank's heat above
the device's minimum operating temperature (104.9 degF), which is about
the lowest temperature usable for a shower. Robust despite
``full_recovery_energy`` being bimodal, since both fields shift
together: the implied tank temperature tracks the thermistor mean to a
standard deviation of 0.57 degF over 12275 samples. Rendered by the CLI
as "Usable Energy".

Removed
-------
- **Misnamed energy fields**: removed ``DeviceStatus.total_energy_capacity``
and ``DeviceStatus.available_energy_capacity`` outright rather than
aliasing them, so a missed rename fails with ``AttributeError`` instead
of silently returning a number 2.5x too large. Use
``full_recovery_energy`` and ``energy_to_setpoint``.

- **Incorrect converter**: removed ``converters.mul_10``, which existed
only to apply the wrong 10 Wh scale. Use
``converters.energy_count_to_wh`` and ``converters.WH_PER_ENERGY_COUNT``.

Fixed
-----
- **Documentation contradicted itself and the code on energy capacity.**
Three incompatible descriptions were published: Watt-hours with no
conversion (protocol reference), Watt-hours with a x10 scale (the code),
and a 0-100 percentage (``how-to/track-energy.rst``,
``reference/python_api/models.rst``, ``project/history.rst``). The
percentage claim was never true of any library version. All are now
consistent.
- ``how-to/track-energy.rst`` documented four fields that do not exist on
``DeviceStatus`` (``dhw_tank_upper_temp``, ``dhw_tank_lower_temp``,
``comp_temp``, ``dhw_heatex_out_temp``); replaced with the real names.
- ``dhwTemperature`` is documented as an outlet temperature but is
measured inside the tank: it tracks ``tankUpperTemperature`` to within
one 0.5 degC step, and the device has no sensor downstream of itself.
Navien's own app agrees, labelling it "DHW Temp." beside the tank
thermistors and showing ``dischargeTemperature`` separately.
- ``docs/explanation/tank-energy.rst`` tabulated ``totalEnergyCapacity``
and ``availableEnergyCapacity`` at ten times their raw wire values,
under column headings naming the raw protocol fields. The series had
been logged through the pre-fix library, which multiplied by 10. The
prose beside the tables ("70.25 raw counts per Kelvin", "35 counts")
was already in true raw counts, so the page contradicted itself by
exactly the factor it exists to correct. Tables are now in raw counts;
1580 counts at a 145.4 degF setpoint matches the test fixtures and the
6320 Wh the CLI reports. No numeric conclusion changes.
- ``docs/explanation/tank-energy.rst`` referred to a field
``hpUpperOnTemperatureSetting``; the protocol name is
``hpUpperOnTempSetting``.
- The setpoint-per-0.5-degC figure is 140 Wh, not 143 Wh, which is what
the documented slope of 70.25 counts/K gives at 4 Wh/count. Corrected
in the changelog, the model field description and the protocol
reference.
- New ``docs/explanation/tank-energy.rst`` records what the two fields
actually measure and the calibration evidence behind the scale change,
including that Navien's own NaviLink app (2.03.00, versionCode 141)
reads neither field, so no vendor-side corroboration exists.

Version 9.2.1 (2026-07-30)
==========================

Expand Down
1 change: 1 addition & 0 deletions docs/explanation/index.rst
Original file line number Diff line number Diff line change
Expand Up @@ -9,3 +9,4 @@ Understanding-oriented deep dives into the library's design and advanced feature

advanced-features
architecture
tank-energy
Loading
Loading