go-multibus

GOcontroll Multibus module service and utilities for Moduline controllers (L4, M1, HMI1) running on i.MX8MM hardware.

Brings a Multibus module up after a controller boot, configures which physical interface each connector pin pair carries, and publishes the battery cell voltages it reads over isoSPI to /dev/shm for the rest of the system.

Two faces over one state machine: a background service that runs at boot, and a terminal UI in the style of go-can for commissioning a machine. What the UI shows is what the service does, because both drive the same code.

Pure standard-library Python 3 - no pyserial, no pyusb, nothing to install on the controller beyond the interpreter it already has.

CLI

gocontroll-usb-hostmode                  # report the OTG port's mode
gocontroll-usb-hostmode --apply          # put it in host mode (needs a reboot)

go-multibus                              # interactive UI (no arguments)
go-multibus daemon                       # background service, systemd entry
go-multibus status                       # one-shot summary, scriptable
go-multibus config                       # show the stored configuration
go-multibus set 3 can                    # change one interface, store it

gocontroll-cellmon list                  # which Multibus devices are present
gocontroll-cellmon info                  # identity, role, capabilities
gocontroll-cellmon status                # isoSPI link counters
gocontroll-cellmon cells                 # one cell snapshot
gocontroll-cellmon watch                 # keep printing snapshots
gocontroll-cellmon interfaces --set can,rs485,can,rs485,isospi
gocontroll-cellmon raw 03 60 f4 6c       # raw isoSPI transfer
gocontroll-cellmon serve                 # publish to /dev/shm

gocontroll-modulebus probe 8             # module bus handshake, over SPI
gocontroll-modulebus start 8             # bootloader -> application
gocontroll-modulebus interfaces 8        # read/write config over SPI

Only one of go-multibus daemon and the UI can run at a time: both open the module's protocol port, and two processes on one CDC port read each other's answers. The UI refuses to start while the service is active and says so.

The bring-up sequence

   reset ──► start ──► configure ──► enumerate ──► running
             (SPI)      (SPI)          (USB)        (USB)
                          ▲                ▲
                          │                └─ the controller now knows which
                          │                   CAN and serial ports are real
                          └─ has to happen before USB comes up
State What happens
reset Pulse the slot reset line; the STM32 restarts into the bootloader
start Tell the bootloader its firmware is current so it starts the application
configure Push the five interface modes over the module bus
enumerate Wait for USB, open the protocol port, apply the cell configuration
running Poll the cell snapshot and publish it

Every step is idempotent and the sequence restarts from the top when the module disappears, so pulling a module and putting it back recovers on its own.

The configuration goes over SPI rather than USB because the controller has to know the interface layout before it initialises the interfaces, and USB is not up at that point. When the module bus does not answer - firmware older than ModuleBus.c - the service falls back to configuring over USB.

Interfaces

The connector carries five interfaces. Pin numbers are for the 26 position uneven slot.

Interface Pins Modes Linux
1 6/5 CAN FD, fixed mb_can1
2 12/13 RS485 or RS232 /dev/mb_serial1
3 18/19 RS485 or CAN FD mb_can2 / /dev/mb_serial2
4 24/25 RS485 or CAN FD mb_can3 / /dev/mb_serial3
5 - isoSPI, fixed /dev/mb_protocol

At most three CAN channels and at most three serial ports can be live at once. mb_can2 and /dev/mb_serial2 are the same connector pins in different modes; only one of each pair carries traffic.

Bus parameters - bitrate, sample point, FD - belong to go-can, the same as for the baseboard buses. go-multibus owns the mode, go-can owns the parameters. The service raises each interface with go-can apply, so the two never disagree about what a bus is running at.

Device names

Names are pinned by debian/udev/81-gocontroll-multibus.rules, because kernel names depend on the controller: a Moduline IV has four onboard mcp251x controllers so the module lands on can4..can6, while an M1 has two and the same module lands on can2..can4. The numbering follows the knowledge base (CAN 1..3, RS485 1..3), not the connector interface numbers.

The tooling falls back to sysfs discovery when the rule is not installed, but anything else on the controller that refers to a name needs it.

Config file

/etc/gocontroll/multibus.json. A missing file is a working configuration.

{
  "slot": 8,
  "interfaces": ["can", "rs485", "can", "rs485", "isospi"],
  "cell_count": 12,
  "module_poll_ms": 100,
  "publish_interval_s": 0.5,
  "bring_up_can": true,
  "can_bitrate": 500000,
  "output": "/dev/shm/gocontroll/multibus-cells.json"
}

interfaces is indexed by connector interface, so interfaces[2] is interface 3 and drives mb_can2.

Published documents

/dev/shm/gocontroll/multibus-cells.json holds the measurements and multibus-state.json where the bring-up sequence stands. Both are written to a temporary file and moved into place with os.replace, which is atomic on Linux: a reader sees either the previous document or the new one, never half of either, and needs no locking.

Branch on valid - it is link_ok && !stale. Failures are published too, rather than leaving the last good document in place, so a reader can tell a dead service from a dead battery link.

Voltages appear twice on purpose: cells_v rounded for display, cells_100uv as the raw device values in the 100 uV steps the LTC681x family uses.

Systemd integration

systemctl enable --now go-multibus       # service + cell publisher

gocontroll-cellmon.service is an alternative for a controller that only wants the cell data and configures the module some other way. Do not run both.

Installing

apt-get install go-multibus

That is everything a fresh controller needs: the tools, the service, the udev naming rules, and gocontroll-usb-hostmode for the OTG port. Both services are enabled but not started - at install time there may be no controller under the filesystem, and on real hardware starting the service resets the module and raises CAN interfaces, which an install should not do underneath a running machine.

systemctl start go-multibus

A controller whose OTG port is still in device mode needs one reboot. gocontroll-usb-hostmode.service runs before go-multibus, notices the port is not in host mode, and applies the change - but that lands in the u-boot environment and the Falcon boot blob, so it only takes effect on the next boot. Until then no module enumerates. On a controller that is already in host mode the service is a no-op that costs one file read.

From a checkout, ./install.sh puts the same files in the same places. A checkout also runs without installing at all: the entry points in bin/ add ../lib to their import path.

Building the package

debian/build-deb.sh 0.1.0 dist

The same script the release workflow runs, so what CI publishes is what you can build and inspect locally. Tagging v* builds it, attaches it to a GitHub release, and tells the GOcontroll apt index to pick it up.

USB host mode

The i.MX8 OTG port comes up as a USB device by default. A module plugged into it never enumerates until the port is a host, and dr_mode = "otg" with a runtime role switch is not enough - the chipidea driver switches the controller but does not fully initialise the PHY, so the high-speed chirp fails and descriptor transfers die with -71. Only dr_mode = "host" gives a full host init.

gocontroll-usb-hostmode sets that, in both places a Moduline can boot from: the otg_mode u-boot variable and the Falcon boot args blob. It backs up everything it touches and verifies what it wrote. Run it without arguments to see the current state; --apply changes it, --revert puts the backups back.

Module firmware

The module needs firmware with MbProto and ModuleBus - version 0.1.0 or later. Older images serve the protocol port as a plain RS485 bridge, and the tooling says so rather than reporting a vague timeout. Firmware lives in the Module-Multibus repository.

Examples

examples/node-red-multibus-cells.json reads the published cell voltages every 500 ms and emits them as JSON, with one signal parsed out as an example. See examples/README.md.

Documentation

Exit codes

Code Meaning
0 Success
1 The module answered with an error, or is unreachable
2 Usage error

License

MIT - see LICENSE.